Osram QUICKTRONIC INTELLIGENT DIM CFL Bedienungsanleitung Seite 61

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 92
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 60
60
Figure 43: QTi DALI/DIM: More luminous flux over an expanded tem-
perature range
Lamp type Min.
temperature at
1 % (3 % CFL)
dimmer setting
Min.
dimmer setting of -20 °C to
+10 °C
T5, CFL* +10 °C 30 %
Table 8: *Amalgam lamps, T5 HO
CONSTANT
(24 W, 39 W, 54 W, 80 W),
CFL (DL
CONSTANT
40 W, 55 W, 80 W)
Attention: For T/E IN PLUS 26 W, 32 W, 42 W, 57 W a dimmer setting
of 50 % min. applies at -20 °C.
3.9.1
Dynamic dimming procedures with amalgam lamps
The frequency of dimmer setting changes is primarily limited by the
inertia of the control input, a passage of the dimming range takes ap-
prox. 200 ms for 1…10 V, and approx. 50 ms for DALI. Thus, rapid
flashing blurs to a middle dimmer setting. At 10 Hz, this effect is al-
ready particularly visible at 1…10 V. No damage to the lamp is to be
expected. A dimming process every 2 s is possible without any prob-
lem.
(T) curves of T5 lamps
0
10
20
30
40
50
60
70
80
90
100
-10 0 10 20 30 40 50 60 70 80
Lamp ambient [°C]
Relative luminous flux [%]
-- 90%
-- T5 Standard
-- T5 CONSTAN T
-- T5 CONSTAN T
of dimmable standard ECG
of QTI DALI/DIM
Seitenansicht 60