Osram Touch DIM LS Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Beleuchtung Osram Touch DIM LS herunter. OSRAM Touch DIM LS User Manual [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
TOUCH DIM LS/PD LI
A B C
D
EVG QTi DALI
1
2
3
4
DA
DA
~
~
N
PE
L
Touch DIM
Sensor
EVG QTi DALI
1
2
3
4
DA
DA
~
~
L
N S
E
F
G
H
Description
Function and application
The TOUCH DIM LS/PD LI sensor regulates the brightness
at the workplace and in ofce areas to increase the working
comfort and to save energy.
The sensor can be installed in luminaires (e.g. oor standing
luminaires) or in false ceilings.
Function
The sensor measures the brightness in the area to be regulated
and keeps this to an adjustable set value by introducing articial
light according to the amount of daylight available.
The sensor also detects the movements of people.
As daylight increases the articial light is reduced . The sensor
no longer detects any motions, it switches the luminaires off.
Construction
The sensor is made up of the following components:
Light sensor (A)
Motion sensor (B)
Housing (C)
Connections (D) for signal line, zero line and phase
Installation
Safety instructions
The sensor must only be installed and put into operation by
a qualied electrician. The applicable safety regulations and
accident prevention regulations must be observed.
WARNING!
Exposed, live cables or damaged housing.
Danger of electric shock!
Only work on the sensor when it is de-
energized.
Disconnect the sensor or luminaire from the
power supply if the housing or plastic lens is
damaged.
CAUTION!
Destruction of the sensor and other devices
through incorrect mounting!
Only use electronic OSRAM ballast coils of the
type QUICKTRONIC INTELLIGENT DALI (QTi
DALI…DIM), HALOTRONIC INTELLIGENT
DALI (HTi DALI…DIM) or OPTOTRONIC
INTELLIGENT DALI (OT…DIM).
Do not operate any other other control units on
the control line.
Do not exceed the maximum number of
ballast coils and maximum overall cable length
between the operating button, sensor and
ballast coil.
Do not connect control line with external
voltage.
Only supply sensor with an AC operating vol-
tage, especially in networks with UPS systems.
Connecting the sensor
E Operating pushbutton: Same phase as sensor.
F Electronic ballast coil (EVG): Connect max. 4 ballast coils.
G Signal line: Max. 10 m.
H Sensor: Cable connection via 3-wires permitted for mains
voltage. Do not switch the sensors in parallel.
Light and motion sensor
Fitting instructions
Continued on the back page!
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - TOUCH DIM LS/PD LI

TOUCH DIM LS/PD LIA B CDEVG QTi DALI1234DADA~~NPELTouch DIMSensorEVG QTi DALI1234DADA~~LN SEFGHDescriptionFunction and applicationThe TOUCH DIM LS/PD

Seite 2 - 40083210230250

80° – 100°80° – 100°IKL M OSRAM GmbH Kunden Service Center Customer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg GermanyTel : +49 (0) 1803 6

Kommentare zu diesen Handbüchern

Keine Kommentare