Seitenansicht 0
OSRAM GmbH
Kunden Service Center
Customer-Service-Center (CSC)
Steinerne Furt 62
86167 Augsburg
Germany
Tel : +49 (0) 1803 677 - 200
(kostenpichtig / charges apply)
Fax.: +49 (0) 1803 677 - 202
www.osram.com
www.osram.de
40503008021384
4050300802138
Light and motion sensor
Fitting instructions
II 2009
LSPD_Multi3_ma0902en_we1.01.indd
LS/PD MULTI 3
Description
Function and application
The LS/PD MULTI 3 sensor detects the presence of people and
measures the intensity of ambient light.
The sensor is installed in lamps.
Construction
The sensor is made up of the following components:
Light sensor (A)
Motion sensor (B)
LED (C)
Connection (D) for supply voltage, light measurement value,
motion signal and signal ground
Housing (E)
Installation
Safety instructions
The sensor must only be installed and put into operation by a
qualied electrician. The applicable safety regulations and ac-
cident prevention regulations must be observed.
WARNING!
Exposed, live cables or damaged housing.
Danger of electric shock!
Only work on the sensor when it is de-energized.
CAUTION!
Destruction of the sensor and other devices through
incorrect mounting!
Only use OSRAM control units of the following
types: DALI MULTI 3/ DIM MULTI 3, DALI
MULTIeco/ MULTIeco, DALI PROFESSIONAL
Sensor Coupler.
Do not connect control line with external voltage.
Note the maximum total line length.
Do not route the sensor line together with the
power or lamp line.
Connecting the sensor
Connect the sensor using the supplied cable or a commercially
available 4-pin cable. If the cable is shortened or lengthened,
ensure that the wiring is correct.
Sensors can be connected in parallel via a Y-branch. For the
maximum number of sensors: see the separate control unit
manual.
F Y-branch (optional)
G Sensor
Continued on the back page!
A B C
D
E
DALI MULTI 3
Sensor
F
G
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - 40503008021384

OSRAM GmbH Kunden Service Center Customer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg GermanyTel : +49 (0) 1803 677 - 200 (kostenpichtig

Seite 2 - Appendix

Fitting (cont.)Selecting the installation locationH Surveillance cone: entire workplace; not on window surfacesI Avoid exposure to direct lightK Av

Kommentare zu diesen Handbüchern

Keine Kommentare