Selecting the installation location
H Optimal mounting height: 2.5 – 3 m. As the mounting height
increases, the detection area increases and sensitivity is
reduced.
J Monitoring cone: Entire workplace; not on window surfaces
K Avoid exposure to direct light.
L Place devices that radiate heat outside of the monitoring
cone.
M Avoid drafts (e.g. from ventilators)
Installation
Safety instructions
The sensor must only be installed and put into operation by
a qualied electrician. The applicable safety regulations and
accident prevention regulations must be observed.
WARNING!
Exposed, live cables.
Danger of electric shock!
Only work on the sensor when it is de-
energised.
CAUTION!
Destruction of the sensor and other devices through
incorrect mounting!
Adhere to the connection diagram.
Protect the sensor and switch contact jointly or
individually via external circuit breakers.
Only operate the sensor when it is closed (the
upper and lower sections of the housing are
rmly connected).
Supply the sensor via an AC power supply
only.
When mounting in luminaires, use a UV-
resistant cable.