Page 2 of 2
A
F2
C
D
F1
F4F3
sp eed es c
A
-
+
G
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
G
Default setting
RESET of control units
Reset the connected control units to the default setting.
Set DIP switch 3 on the back of the wall operating unit (G) to
OFF.
Press central button (C).
Set DIP switch 3 to ON again.
Basic settings
Use DIP switches 1 and 2 on the back (G).
Do not change DIP switches 4-8.
Function DIP switch
Signal transmission
type
Radio 1 ON
Wired 1 OFF
Access to
user settings
Enable 2 ON
Disable 2 OFF
Conformity with the relevant EU directives is
conrmed by the CE symbol.